Gases and Gas Accessories
Filtered Search Results

Fisherbrand™ High-Purity Brass Single-Stage Regulators
Made from materials with surface finish that will not outgas impurities into the gas stream. For high purity noncorrosive gases
Pressure Range (Inlet) | 3000 psi |
---|---|
Diameter (English) Gauge | 2 in. |
Operating Temperature Range (English) | -°F to +140°F |
Diaphragm Material | 316L Stainless Steel |
Filter Material | 10μ Stainless Steel |
Material | Chrome-plated Brass |
For Use With (Application) | Ideal for instrument and OEM applications employing very high purity, noncorrosive gases and gas mixtures where some variations in delivery pressure can be tolerated |
Diameter (Metric) Gauge | 5.08 cm |
Operating Temperature Range (Metric) | -4°C to +60°C |
Type | Gas Regulator |
Connection Type | 0.25 in. NPT outlet port |
Seal Material | Viton™ |
No. of Stages | Single |
Seat Material | PCTFE |
Fisherbrand™ High-Pressure Single-Stage Gas Cylinder Regulators
For noncorrosive general purpose gases. Single-Stage Regulators feature reliable piston design for precise gas control at high delivery pressure up to 1500PSI and 3000PSI
Type | Gas Regulator |
---|---|
Diameter (English) Gauge | 2.5 in. |
Connection Type | 0.25 in. NPT inlet |
Filter Material | Sintered Bronze |
Material | Brass |
For Use With (Application) | Use in hydrogenation, catalytic reduction, dead-end and pressure testing |
Diameter (Metric) Gauge | 6.35 cm |
No. of Stages | Single |
Seat Material | PCTFE |
Fisherbrand™ R31B Series High Purity Low Flow Gas Regulators
Diaphragm-Sensed Dual-Stage Regulators designed for analytical applications where a consistent outlet pressure and flow are desired. For Noncorrosive High Purity Gases.
Pressure Range (Inlet) | 3000 psi |
---|---|
Pressure Range (Outlet) | 30 in. Hg Vac-100 psi |
Outboard Leakage | 2 x 10-8 atm.cc/sec. heat inlet pressure: 1500 psi |
Operating Temperature Range (English) | -40°F to +165°F |
Diaphragm Material | 316L Stainless Steel |
Material | Nickel-plated Brass |
Knob Material | ABS Plastic |
For Use With (Application) | Cylinder, research laboratories, gas chromatography, process analyzers, petrochemical industry, power plant |
Operating Temperature Range (Metric) | -40°C to +74°C |
Includes | Diaphragm valve |
Bonnet Material | Nickel-plated Brass |
Gauge Pressure (English) | 2 in. |
Front Panel Thickness | 0.25 in. |
Type | Gas Regulator |
Gauge Pressure (Metric) | 5.08 cm |
Connection Type | 0.25 in. GENLOK |
Max. Outlet Pressure | 250 psi |
Weight (English) | 4.03 lb. |
Seal Material | Metal |
Inboard Leakage | 2 x 10-8 atm.cc/sec. He |
No. of Stages | Dual |
Seat Material | PCTFE |
Weight (Metric) | 1.82 kg |
Fisherbrand™ Ultra High Purity Hydrogen Gas Generators for GC Carrier and Fuel Gas
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Ultra High Purity Range of hydrogen gas generators offer convenient and safe alternatives to cylinder gas for gas chromatography and fuel can carrier gas applications.
Connections | 1/8 in. Compression |
---|---|
Outlet Port | compression fitting |
Height (Metric) | 45.6 cm |
Electrical Requirements | Universal (90V - 264V 50/60Hz) |
Warranty | 12 months on system, 24 months on PEM cell |
Outlet Pressure | 10 to 100 psig |
Depth (English) | 18.5 in. |
Width (English) | 13.5 in. |
For Use With (Application) | Gas chromatography, fuel gas, carrier gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), nitrogen phosphorous detector carrier gas (NPD), thermal conductivity detector carrier gas (TCD), Electrolytic Conductivity Detector reactio |
Pressure | 10 to 100 psig |
Width (Metric) | 34.2 cm |
Includes | US, UK and EU power cord, Water drain tube, DI cartridge, User guide |
Max. Ambient Operating Temperature | 5°C to 40°C (41°F to104°F) |
Type | Hydrogen Carrier Gas Generator |
For Use With (Equipment) | Gas Chromatograph |
Depth (Metric) | 47 cm |
Voltage | 90-264 Universal Power Supply |
Frequency | 50/60 Hz |
Certifications/Compliance | CE, cULus |
Height (English) | 18 in. |
Fisherbrand™ High Purity Hydrogen Gas Generators For GC Fuel Gas
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
High purity range of hydrogen gas generators offer convenient and safe alternatives to cylinder gas for gas chromatography.
Connections | 1/8 in. Compression |
---|---|
Outlet Port | compression fitting |
Height (Metric) | 45.6 cm |
Electrical Requirements | Universal (90V - 264V 50/60Hz) |
Outlet Size | 1/8 in. |
Warranty | 12 months on system, 24 months on PEM cell |
Outlet Pressure | 10 to 100 psig |
Depth (English) | 17 in. |
Width (English) | 13.5 in. |
For Use With (Application) | Gas chromatography, fuel gas, flame ionization detector (GC-FID) flame photometric detector (GC-FPD), Electrolytic Conductivity Detector (ELCD & Hall ELCD), other combustion detectors |
Pressure | 10 to 100 psig |
Width (Metric) | 34.2 cm |
Includes | US, UK and EU power cord, Water drain tube, DI cartridge, User Guide |
Max. Ambient Operating Temperature | 5°C to 40°C (41°F to104°F) |
Type | Hydrogen Fuel Gas Generator |
For Use With (Equipment) | Gas Chromatograph |
Depth (Metric) | 43.7 cm |
Voltage | 90-264 Universal Power Supply |
Frequency | 50/60 Hz |
Certifications/Compliance | CE, CSA, cULus |
Weight (Metric) | 23 kg (Full of water) |
Height (English) | 18 in. |
Fisherbrand™ Gentec™ P4400 Point Of Use Gas Control Panel
Designed for accurate control of gases in low flow applications
Fisherbrand™ Zero Air Generators For GC Fuels
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Zero air generators produce a continuous stream of organic impurity-free air from external dry compressed air source and offer superior limits of detection over and above other modes of supply.
Outlet Port | compression fitting |
---|---|
Height (Metric) | 45.5 cm |
Warranty | 12 months on system |
Outlet Pressure | Up to 135 psig depending on inlet pressure |
Depth (English) | 16.7 in. |
Width (English) | 13.5 in. |
Purity | Gas purity: <0.1ppm total hydrocarbon as CH4 |
For Use With (Application) | Gas chromatography, Flame support gas, Flame ionization detector (GC-FID) Flame photometric detector (GC-FPD) |
Pressure | Varies with inlet. 5 psig less than inlet |
Width (Metric) | 34.2 cm |
Max. Ambient Operating Temperature | 5°C to 40°C (41°F to104°F) |
Type | Zero Air Gas Generator |
For Use With (Equipment) | Gas Chromatograph |
Depth (Metric) | 42.5 cm |
Max. Inlet Air Temperature | 104°F |
Certifications/Compliance | CE, cULus |
Weight (Metric) | 14.2 kg |
Height (English) | 18 in. |
Fisherbrand™ Single-Stage Lecture Bottle Gas Regulators
Lightweight, compact, single-stage, lecture bottle regulators for noncorrosive gases
Fisherbrand™ Zero Air Generators
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Zero air gas generators provide a convenient and safe alternative to cylinder gas for gas chromatography combustion applications. These systems remove organic impurities from existing compressed air sources allowing the user to eliminate expensive bottled zero grade air from their lab.
Connections | 1.4 in. NPT (female) |
---|---|
Outlet Port | 1/4 in. NPT (female) |
Height (Metric) | 30 cm |
Outlet Size | 1/4 in. |
Warranty | 12 months on system |
Outlet Pressure | Up to 135 psig depending on inlet pressure |
Depth (English) | 3 in. |
Purity | Gas purity: <0.1ppm total hydrocarbon as CH4 |
For Use With (Application) | Gas chromatography, Flame ionization detector (GC-FID) flame photometric detector (GC-FPD), Electrolytic Conductivity Detector (ELCD & Hall ELCD), other combustion detectors |
Pressure | Varies with inlet. 5 psig less than inlet |
Width (Metric) | 25 cm |
Includes | US power cord, User guide |
Max. Ambient Operating Temperature | 5°C to 40°C (41°F to104°F) |
Flow Rate | 1 L/min. |
Type | Zero Air Gas Generator |
Capacity | 1 L/min |
No. of FIDs | 2-3 |
For Use With (Equipment) | Gas Chromatograph |
Depth (Metric) | 8 cm |
Frequency | 60 Hz |
Max. Inlet Air Temperature | 104°F |
Certifications/Compliance | CE, CSA, cULus |
Weight (Metric) | 3 kg |
Height (English) | 12 in. |
DWK Life Sciences™ Kimble™ Kontes™ Airless-ware™ Vacuum Flask
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Facilitates heating, stirring and solvent stripping without impairing ease of liquid and solid transfer
BINDER™ Inert Gas Connection
Small and Specialty Supplier Partner
Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More

Small and/or specialty supplier based on Federal laws and SBA requirements.
Learn More
Inert gas connection with gas inlet and outlet. Includes additional measures for the greatest possible impermeability to gas. Not in conjunction with access port or interior lighting option.
Weight (English) | 2.20 lb. |
---|---|
Volume (Metric) Gas | None |
Weight (Metric) | 1 kg |
MilliporeSigma™ Supelco™ Purge/Trap A
Specific configurations available for a variety of instruments
Type | Purge/Trap A |
---|---|
For Use With (Application) | Industrial Hygiene |
Oxiclear™ Disposable Oxygen/Moisture Trap, Sold by MilliporeSigma™ Supelco™
Reduces oxygen to less than 1 ppm when the incoming level is below 10 ppm.
Type | Oxygen/Moisture Trap |
---|---|
Length (Metric) | 19 cm |
Diameter (Metric) Outer | 48 mm |
Diameter (English) Outer | 1.875 in. |
Length (English) | 7.5 in. |
For Use With (Application) | Reduces Oxygen, Removes Moisture and Organic Contaminants |
Product Line | Oxiclear™ |
MilliporeSigma™ Supelco™ Purge/Trap C
Specific configurations available for a variety of instruments
Type | Purge/Trap C |
---|---|
For Use With (Application) | Industrial Hygiene |
MilliporeSigma™ Supelco™ domnick hunter™ NITROX™ UHP Hydrogen Generator
A safe and economic alternative to high pressure gas cylinders
Type | Hydrogen Gas Generator |
---|---|
For Use With (Equipment) | Any Laboratory Instrument Requiring a Supply of Ultra High Purity Hydrogen |
Purity | 99.999% Pure Hydrogen |
For Use With (Application) | Carrier Gas and Fuel Gas Applications |